{"id":10699,"date":"2024-02-28T19:39:38","date_gmt":"2024-02-28T19:39:38","guid":{"rendered":"https:\/\/teczhar.com\/?post_type=product&#038;p=10699"},"modified":"2024-02-28T19:45:01","modified_gmt":"2024-02-28T19:45:01","slug":"fluke-289-fvf-flukeview-forms-combo-kit","status":"publish","type":"product","link":"https:\/\/www.teczhar.com\/?product=fluke-289-fvf-flukeview-forms-combo-kit","title":{"rendered":"FLUKE 289\/FVF (FLUKEVIEW FORMS COMBO KIT)"},"content":{"rendered":"<p><strong>SPECIFICATIONS FLUKE 289\/FVF<\/strong><\/p>\n<p><strong>DC volts<\/strong><\/p>\n<p>Range and resolution: 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V<\/p>\n<p>Basic accuracy: 0.025 %<\/p>\n<p><strong>AC volts<\/strong><\/p>\n<p>Range and resolution: 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V<\/p>\n<p>Basic accuracy: 0.4 % (true-rms)<\/p>\n<p><strong>DC current<\/strong><\/p>\n<p>Range and resolution: 500.00 \u03bcA, 5000.0 \u03bcA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A<\/p>\n<p>Basic accuracy: 0.15 %<\/p>\n<p><strong>AC current<\/strong><\/p>\n<p>Range and resolution: 500.00 \u03bcA, 5000.0 \u03bcA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A<\/p>\n<p>Basic accuracy: 0.7%(true-rms)<\/p>\n<p><strong>Temperature (excluding probe)<\/strong><\/p>\n<p>Range and resolution: -200.0 \u00b0C to 1350.0 \u00b0C (-328.0 \u00b0F to 2462.0 \u00b0F)<\/p>\n<p>Basic accuracy: 1.0 %<\/p>\n<p><strong>Resistance<\/strong><\/p>\n<p>Range and resolution: 50.000 W (289 only), 500.00 W, 5.0000 kW, 50.000 kW, 500.00 kW, 5.0000 MW, 50.00 MW, 500.0 MW<\/p>\n<p>Basic accuracy: 0.05 %<\/p>\n<p><strong>Capacitance<\/strong><\/p>\n<p>Range and resolution: 1.000 nF,10.00 nF 100.0 nF, 1.000 \u03bcF, 10.00 \u03bcF, 100.0 \u03bcF, 1000 \u03bcF, 10.00 mF, 100.00 mF<\/p>\n<p>Basic accuracy: 1.0 %<\/p>\n<p><strong>Frequency<\/strong><\/p>\n<p>Range and resolution: 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz<\/p>\n<div class=\"column\">\n<p>Basic accuracy: 0.005 % + 1<\/p>\n<\/div>\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<h2><strong>Introduction Fluke 289\/FVF<\/strong><\/h2>\n<p>Maximize productivity with the combined\u00a0<a href=\"https:\/\/techmaster.com.vn\/en\/fluke-17b-plus-digital-multimeter\/\">Fluke 289<\/a>\u00a0and FlukeView Forms Combo Kit. With built-in data logger and TrendCapture capability, the 289 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs. Using FlukeView Forms soft- ware allows you to overlay your logged data from six meters or six time periods to find cause and effect relationships or for condition monitoring. Turn your data into meaningful graphs and tables for a professional report or analyze individual readings or series of measurements. The 289\/FVF combo kit gives you a practical and affordable approach to predictive maintenance.<\/p>\n<h2><strong>Functions and Features\u00a0<\/strong><\/h2>\n<p>Multiple on-screen displays: Yes<\/p>\n<p>LoZ: Yes<\/p>\n<p>50 ohm range: Yes<\/p>\n<p>Filter for measure- ments on motor drives: Yes<\/p>\n<p>True-rms ac band- width: 100 kHz<\/p>\n<p>DBV\/dBm: Yes<\/p>\n<p>DC mV resolution: 1 \u03bcV<\/p>\n<p>Megohm range: 500 MW<\/p>\n<p>Conductance: 50.00 nS<\/p>\n<p>Continuity beeper: Yes<\/p>\n<p>Temperature (\u00b0C and \u00b0F): -200 \u00b0C to 1350 \u00b0C<\/p>\n<p>Battery\/fuse access: Yes\/Yes<\/p>\n<p>Elapse time clock: Yes<\/p>\n<p>Time of day clock: Yes<\/p>\n<p>Min-Max-Avg: Yes<\/p>\n<p>Frequency: Yes<\/p>\n<p>Duty cycle\/pulse width: Yes<\/p>\n<p>Info button on board help: Yes<\/p>\n<p>Hold: Yes<\/p>\n<p>Isolated optical interface: Yes<\/p>\n<p>Auto\/touch hold: Yes<\/p>\n<p>Reading memory: Yes<\/p>\n<p>Log to PC: Yes<\/p>\n<p>On board logging with TrendCapture: Yes<\/p>\n<p>Logging memory (Fluke 289): 180 hours<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2><strong>Features<\/strong><\/h2>\n<ul>\n<li>True-rms ac band- width: 100 kHz<\/li>\n<li>DC mV resolution: 1 \u03bcV<\/li>\n<li>Megohm range: 500 MW<\/li>\n<li>Conductance: 50.00 nS<\/li>\n<li>Temperature (\u00b0C and \u00b0F): -200 \u00b0C to 1350 \u00b0C<\/li>\n<li>Logging memory: 180 hours<\/li>\n<\/ul>\n","protected":false},"featured_media":10657,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_themeisle_gutenberg_block_has_review":false},"product_cat":[137],"product_tag":[],"_links":{"self":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10699"}],"collection":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10699"}],"version-history":[{"count":1,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10699\/revisions"}],"predecessor-version":[{"id":10703,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10699\/revisions\/10703"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/media\/10657"}],"wp:attachment":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10699"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=10699"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=10699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}