{"id":10706,"date":"2024-02-28T19:45:16","date_gmt":"2024-02-28T19:45:16","guid":{"rendered":"https:\/\/teczhar.com\/?post_type=product&#038;p=10706"},"modified":"2024-02-28T19:52:27","modified_gmt":"2024-02-28T19:52:27","slug":"fluke-vr1710-single-phase-power-quality-recorder-voltage-recorder","status":"publish","type":"product","link":"https:\/\/www.teczhar.com\/?product=fluke-vr1710-single-phase-power-quality-recorder-voltage-recorder","title":{"rendered":"FLUKE VR1710 SINGLE PHASE POWER QUALITY RECORDER &#038; VOLTAGE RECORDER"},"content":{"rendered":"<section id=\"fluke-product-atf-title\">\n<p id=\"fluke-product-display-title\"><strong>SPECIFICATIONS FLUKE VR1710 SINGLE PHASE POWER QUALITY RECORDER &amp; VOLTAGE RECORDER<\/strong><\/p>\n<p><strong>Operating voltage:\u00a0<\/strong>70 V to 280 V<\/p>\n<p><strong>Min\/Max\/Avg RMS value:\u00a0<\/strong>Resolution 0.125 V<\/p>\n<p><strong>Number of events:\u00a0<\/strong>175,000<\/p>\n<p><strong>Dips\/interruptions:\u00a0<\/strong>Yes<\/p>\n<p><strong>Time resolution:\u00a0<\/strong>5 ms<\/p>\n<p><strong>Voltage resolution:\u00a0<\/strong>0.125 V<\/p>\n<p><strong>Over-voltages:\u00a0<\/strong>Yes<\/p>\n<p><strong>Frequency:\u00a0<\/strong>Yes<\/p>\n<p><strong>Harmonics measurement:\u00a0<\/strong>EN 61000-4-7 (up to 32nd)<\/p>\n<h4><strong>Flicker measurement\u00a0<\/strong><strong>(Fluke VR1710)<\/strong><\/h4>\n<h4>EN 61000-4-15 and Delta V\/V%<\/h4>\n<h4><strong>Number of recording channels<br \/>\n<\/strong><\/h4>\n<h4>1 Phase to Neutral<strong><br \/>\n<\/strong><\/h4>\n<p>2 Phase\/Neutral to Ground<\/p>\n<p><strong>Recording time:\u00a0<\/strong>1 day to 339 days depending on average time from 1 second to 20 minutes<\/p>\n<p><strong>Transients:\u00a0<\/strong>Yes<\/p>\n<p><strong>Frequency range:\u00a0<\/strong>50 Hz \u00b11 Hz and 60 Hz \u00b11 Hz<\/p>\n<p><strong>Safety category rating:\u00a0<\/strong>CAT II 300 V<\/p>\n<p><strong>Introduction Fluke VR1710<\/strong><\/p>\n<\/section>\n<section id=\"fluke-product-atf-slides\">\n<div>\n<p>The Fluke VR1710 Power Quality Recorder, is a single-phase, plug-in voltage quality recorder that offers an extremely easy-to-use solution for detecting and recording power quality problems, allowing for immediate action and less downtime. The VR1710 single phase recorder satisfies the needs of maintenance and facilities management personnel in industrial, utilities, and large service organizations where reliable power quality is essential to the operation of the business. Power quality parameters including RMS average, transients, flicker, and harmonics up to the 32nd are recorded using a user-selected average period from 1 seconds to 20 minutes.<\/p>\n<ul>\n<li><strong>Other useful features:<\/strong><\/li>\n<\/ul>\n<p>\u2013 Offers continuous recording of all values with no gaps to create a complete picture with one instrument<br \/>\n\u2013 Measures Min\/Max\/Average RMS values (1\/4 cycle) with time stamp so you can quickly see what happened and when<br \/>\n\u2013 Presents actual transient display (&gt;100 \u03bcs) with time stamp to help you identify power quality issues quickly with included graphical software<br \/>\n\u2013 Records flicker to EN 61000-4-15 and individual harmonic and THD values with trends to help you easily determine if the problem is power quality or equipment related<br \/>\n\u2013 Provides statistical analysis of single-phase voltage events. Reduces analysis time by tracking event quantities and magnitudes<br \/>\n\u2013 Includes PowerLog software package for quick download, analysis, and automatic reporting<\/p>\n<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"features-title\"><strong>Key Features<\/strong><\/h2>\n<div id=\"keyfeature_content\">\n<ul>\n<li>Single-phase, plug-in voltage quality recorder for detecting and recording power quality problems<\/li>\n<li>Records voltage trends, dropouts, and power quality to pinpoint the root cause<\/li>\n<li>Plugs directly into the mains power socket to capture data<\/li>\n<li>Presents a clear graphical summary of data and a quick overview of key power quality parameters<\/li>\n<\/ul>\n<\/div>\n","protected":false},"featured_media":10642,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_themeisle_gutenberg_block_has_review":false},"product_cat":[137],"product_tag":[],"_links":{"self":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10706"}],"collection":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10706"}],"version-history":[{"count":1,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10706\/revisions"}],"predecessor-version":[{"id":10713,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10706\/revisions\/10713"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/media\/10642"}],"wp:attachment":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10706"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=10706"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=10706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}