{"id":10710,"date":"2024-02-28T19:51:18","date_gmt":"2024-02-28T19:51:18","guid":{"rendered":"https:\/\/teczhar.com\/?post_type=product&#038;p=10710"},"modified":"2024-02-28T19:53:45","modified_gmt":"2024-02-28T19:53:45","slug":"fluke-1630-fc-earth-ground-clamp","status":"publish","type":"product","link":"https:\/\/www.teczhar.com\/?product=fluke-1630-fc-earth-ground-clamp","title":{"rendered":"FLUKE 1630 FC EARTH GROUND CLAMP"},"content":{"rendered":"<p><strong>SPECIFICATIONS FLUKE 1630 FC EARTH GROUND CLAMP<\/strong><\/p>\n<p><strong>Maximum voltage to earth ground:<\/strong>\u00a01000 V<\/p>\n<p><strong>Battery type :\u00a0<\/strong>AA alkaline IEC\/EN LR6 (x4)<\/p>\n<p><strong>Battery life:\u00a0<\/strong>More than 15 hours*<\/p>\n<p>* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off<\/p>\n<p><strong>Frequency range:\u00a0<\/strong>40 Hz to 1 kHz<\/p>\n<p><strong>Ingress protection:\u00a0<\/strong>IEC\/EN 60529: IP30 with jaw closed<\/p>\n<p><strong>LCD:\u00a0<\/strong>Digital reading\u00a0\u00a0 9999 counts<\/p>\n<p><strong>Refresh rate:\u00a0<\/strong>4 per second<\/p>\n<p><strong>Operating temperature:\u00a0<\/strong>-10 \u00b0C to + 50 \u00b0C<\/p>\n<p><strong>Storage temperature:<\/strong>\u00a0\u00a0\u00a0\u00a0 -20 \u00b0C to + 60 \u00b0C<\/p>\n<p><strong>Operating humidity :\u00a0<\/strong><\/p>\n<p>Non condensing (&lt;10 \u00b0C) (&lt; 50 \u00b0F)<\/p>\n<p>\u226490% RH (at 10 \u00b0C to 30 \u00b0C [50 \u00b0F to 86 \u00b0F])<\/p>\n<p>\u226475% RH (at 30 \u00b0C to 40 \u00b0C [86 \u00b0F to 104 \u00b0F])<\/p>\n<p>\u226445% RH (at 40 \u00b0C to 50 \u00b0C [104 \u00b0F to 122 \u00b0F])<\/p>\n<p>(Non condensing)<\/p>\n<p><strong>Operating altitude:\u00a0<\/strong>\u00a02000 m (6561 feet)<\/p>\n<p><strong>Storage altitude:<\/strong>\u00a012 000 m (39,370 feet)<\/p>\n<p><strong>Reference temperature:<\/strong>\u00a023 \u00b0C \u00b15 \u00b0C (73 \u00b0F \u00b19 \u00b0F)<\/p>\n<p><strong>Temperature coefficient:<\/strong>\u00a00.15% x (specified accuracy)\/ \u00b0C (&lt;18 \u00b0C or &gt;28 \u00b0C [&lt;64.4 \u00b0F or &gt;82.4 \u00b0F])<\/p>\n<p><strong>Overload indication:<\/strong>\u00a0OL<\/p>\n<p><strong>Data logging capacity:<\/strong>\u00a0Minimum of 32,760 measurements<\/p>\n<h4><strong>Display reading specification with standard loop resistance<\/strong><\/h4>\n<p>+ Input (\u2126): 0.474<\/p>\n<p>Minimum: 0.417<\/p>\n<p>Maximum: 0.531<\/p>\n<p>+ Input (\u2126): 0.5<\/p>\n<p>Minimum: 0.443<\/p>\n<p>Maximum: 0.558<\/p>\n<p>+ Input (\u2126): 10<\/p>\n<p>Minimum: 9.55<\/p>\n<p>Maximum: 10.45<\/p>\n<p>+ Input (\u2126): 100<\/p>\n<p>Minimum: 96<\/p>\n<p>Maximum: 104<\/p>\n<p><strong>Safety<\/strong><\/p>\n<p><strong>General:<\/strong><\/p>\n<p>IEC\/EN 61010-1: Pollution Degree 2 IEC\/EN 61557-1<\/p>\n<p><strong>Measurement:<\/strong><\/p>\n<p>IEC\/EN 61010-2-032: CAT IV 600 V \/ CAT III 1000 V<\/p>\n<p><strong>Current clamp for leakage current measurements<\/strong><\/p>\n<p>IEC\/EN 61557-13: Class 2, \u226430 A\/m<\/p>\n<p><strong>Resistance to earth:<\/strong>\u00a0IEC\/EN 61557-5<\/p>\n<p><strong>Effectiveness of thepProtective measures:\u00a0<\/strong>IEC\/EN 61557-16<\/p>\n<p><strong>Electromagnetic compatibility (EMC)<\/strong><\/p>\n<p><strong>International<\/strong><\/p>\n<ul>\n<li>IEC\/EN 61326-1: Portable Electromagnetic Environment<\/li>\n<li>CISPR 11: Group 1, Class B, IEC\/EN 61326-2-2<\/li>\n<\/ul>\n<p><strong>Korea (KCC)<\/strong><\/p>\n<p>Class A equipment (Industrial Broadcast &amp; Communications Equipment)<\/p>\n<p><strong>USA (FCC)<\/strong><\/p>\n<p>47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103<\/p>\n<h4><strong>Wireless Radio<\/strong><\/h4>\n<p><strong>Frequency range:\u00a0<\/strong>2412 MHz to 2462 MHz<\/p>\n<p><strong>Output power:<\/strong>\u00a0&lt;10 mW<\/p>\n<p><strong>Radio frequency certification:\u00a0<\/strong>FCC ID:T68-FBLE IC:6627A-FBLE<\/p>\n<p><strong>General Specifications<\/strong><\/p>\n<p><strong>Conductor size:<\/strong>\u00a040 mm (1.57 in) approximately<\/p>\n<p><strong>Dimensions (L x W x H):<\/strong>\u00a0283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)<\/p>\n<p><strong>Weight:<\/strong>\u00a0880g (31 oz)<\/p>\n<p><strong>Earth Ground Loop Resistance<\/strong><\/p>\n<p>+ Range: 0.025 \u2126 to 0.249 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 1.5% + 0.02 \u2126<\/p>\n<p>+ Range: 0.250 \u2126 to 0.999 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 1.5% + 0.05 \u2126<\/p>\n<p>+ Range: 1.000 \u2126 to 9.999 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 1.5% + 0.10 \u2126<\/p>\n<p>+ Range: 10.00 \u2126 to 49.99 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 1.5% + 0.30 \u2126<\/p>\n<p>+ Range: 50.00 \u2126 to 99.99 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 1.5% + 0.50 \u2126<\/p>\n<p>+ Range: 100.0 \u2126 to 199.9 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 3.0% + 1.0 \u2126<\/p>\n<p>+ Range: 200.0 \u2126 to 399.9 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 5.0% + 5.0 \u2126<\/p>\n<p>+ Range: 400 \u2126 to 599 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 10.0% + 10 \u2126<\/p>\n<p>+ Range: 600 \u2126 to 1500 \u2126<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + \u2126): 20.00%<\/p>\n<p><small><sup>1<\/sup>\u00a0 Loop resistance with no inductance, conductor centered and perpendicular to jaw<\/small><\/p>\n<h4><strong>Earth ground leakage current mA<\/strong><\/h4>\n<p><strong>Autorange 50\/60 Hz, True rms, crest factor CF \u22643<\/strong><\/p>\n<p>+ Range: 0.200 mA to 3.999 mA<\/p>\n<p>Resolution: 1 \u03bcA<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + mA): 2.0% + 0.05 mA<\/p>\n<p>+ Range: 4.00 mA to 39.99 mA<\/p>\n<p>Resolution: 10 \u03bcA<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + mA): 2.0% + 0.03 mA<\/p>\n<p>+ Range: 40.0 mA to 399.9 mA<\/p>\n<p>Resolution: 100 \u03bcA<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + mA): 2.0% + 0.3 mA<\/p>\n<p>+ Range: 0.400 A to 3.999 A<\/p>\n<p>Resolution: 1 mA<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + mA): 2.0% + 3 mA<\/p>\n<p>+ Range: 4.00 A to 39.99 A<\/p>\n<p>Resolution: 10 mA<\/p>\n<p>Accuracy<sup>1<\/sup>\u00a0 \u00b1 (% of reading + mA): 2.0% + 30 mA<\/p>\n<p><small><sup>1<\/sup>\u00a0Applies to signal frequency<\/small><\/p>\n<ul>\n<li><small>40 Hz to 1 kHz with filter set to OFF<\/small><\/li>\n<li><small>40 Hz to 70 Hz with filter se to ON<\/small><\/li>\n<\/ul>\n<h2 id=\"fluke-product-display-title\"><strong>Introduction Fluke 1630 FC Earth Ground Clamp<\/strong><\/h2>\n<p>The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don\u2019t have access to soil to place auxiliary test stakes.<\/p>\n<h3><strong>Earth ground ac leakage current measurement<\/strong><\/h3>\n<p>\u2013 Identify ac leakage currents without disconnecting the earth ground stake from the grounding system\u2013ideal for system troubleshooting.<br \/>\n\u2013 Rugged heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.<\/p>\n<h3><strong>Logging measurements<\/strong><\/h3>\n<p>\u2013 The earth ground clamp saves time by automatically recording data at pre-set intervals<br \/>\n\u2013 Saves up to 32,760 measurements in memory at the set logging interval.<br \/>\n\u2013 Saves time by recording and storing measured values.<\/p>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"features-title\"><strong>Key Features<\/strong><\/h2>\n<div id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\">\n<div id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\">\n<ul>\n<li>Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes.<\/li>\n<li>AC Leakage Current Measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system<\/li>\n<li>Rugged: Heavy-duty clamp jaw stays in alignment and calibration on tough jobsites<\/li>\n<li>Logging measurement: Saves up to 32,760 measurements in memory<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"featured_media":10637,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_themeisle_gutenberg_block_has_review":false},"product_cat":[137],"product_tag":[],"_links":{"self":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10710"}],"collection":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10710"}],"version-history":[{"count":1,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10710\/revisions"}],"predecessor-version":[{"id":10714,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/product\/10710\/revisions\/10714"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=\/wp\/v2\/media\/10637"}],"wp:attachment":[{"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10710"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=10710"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.teczhar.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=10710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}